Specifications:
|
Maximum voltage between any terminal and earth ground | 600 V |
Surge protection | 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
Display | Digital: 6,000 counts, updates 4 per second |
Bar graph | 33 segments, updates 32 per second |
Operating Temperature | -10 °C to + 50 °C |
Storage Temperature | -40 °C to + 60 °C |
Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery Life | 400 hours typical, without backlight |
|
Accuracy Specifications:
|
DC millivolts | Range: 600.0 mV |
Resolution: | 0.1 mV |
Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 |
DC volts | Range/Resolution: 6.000 V / 0.001 V |
Range/Resolution: | 60.00 V / 0.01 V |
Range/Resolution: | 600.00 V / 0.1 V |
Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 |
AC millivolts1 true-rms | Range: 600.0 mV |
Resolution: | 0.1 mV |
Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) |
AC volts1 true-rms | Range/Resolution: 6.000 V / 0.001 V |
Range/Resolution: | 60.00 V / 0.01 V |
Range/Resolution: | 600.0 V / 0.1 V |
Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) |
Continuity | Range: 600 Ω |
Resolution: | 1 Ω |
Accuracy: | Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 Ωs or longer. |
Ohms | Range/Resolution: 600.0 Ω / 0.1 Ω |
Range/Resolution: | 6.000 kΩ / 0.001 kΩ |
Range/Resolution: | 60.00 kΩ / 0.01 kΩ |
Range/Resolution: | 600.0 kΩ / 0.1 kΩ |
Range/Resolution: | 6.000 MΩ / 0.001 MΩ |
Accuracy: | 0.9 % + 1 |
Range/Resolution: | 40.00 MΩ / 0.01 MΩ |
Accuracy: | 5 % + 2 |
Diode Test | Range/Resolution: 2.00 V / 0.001 V |
Accuracy: | 0.9% + 2 |
Capacitance | Range/Resolution: 1000 nF / 1 nF |
Range/Resolution: | 10.00 µF / 0.01 µF |
Range/Resolution: | 100.0 µF / 0.1 µF |
Range/Resolution: | 9999 µF / 1 µF |
Range/Resolution: | 100 µF to 1000 µF |
Accuracy: | 1.9% + 2 |
Range/Resolution: | > 1000 µF |
Accuracy: | 5% + 20% |
Lo-Z Capacitance | Range: 1 nF to 500 µF |
Accuracy: | 10% + 2 typical |
AC amps true-rms (45 Hz to 500Hz) | Range/Resolution: 6.000 A / 0.001 A |
Range/Resolution: | 10.00 A / 0.01 A |
Accuracy: | 1.5% + 3 |
| 20 A overload for 30-seconds max |
DC amps | Range/Resolution: 6.000 A / 0.001 A |
Range/Resolution: | 10.00 A / 0.01 A |
Accuracy: | 1.0% + 3 |
| 20 A overload for 30-seconds max |
Hz (V or A input)2 | Range/Resolution: 99.99 Hz / 0.01 Hz |
Range/Resolution: | 999.9 Hz / 0.01 Hz |
Range/Resolution: | 9.999 kHz / 0.001 kHz |
Range/Resolution: | 50 kHz / 0.01 kHz |
Accuracy: | 0.1% + 2 |
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage
|